PROTON
Intensive Care Ventilator

PROTON Intensive Care Ventilator
  • Non-invasive Ventilation
  • Display of All Lung Mechanics
  • Large External Colour LCD Monitor
  • Comprehensive Monitoring
  • In-built Nebuliser
  • Easy Last Start-up
  • Easy to Use
  • Multiple Unit Monitoring Connectivity

Technical Specifications

Operational Parameters

Modes CMV - Volume Controlled
  SIMV - Volume Controlled
  ASSIST - Apnea Back-Up
  PSV-SIMV
 

PSV - Apnea Back-Up

  CMV - PCV / ASSIST - PCV / SIMV - PCV
  Bi - NIV / CPAP

Displayed Parameters

Breaths per Minute (BPM)

0 to 120

Tidal Volume (VT)

30 to 300 cc in Pediatric Mode

300 to 3000 cc in Adult Mode

Inspiratory (VT)

0.16 to 4 seconds or 20 to 80% of Breath cycle

Peak Flow Rate Pediatric
Adult
6 to 50 lit./min maximum
6 to 150 lit./min maximum
Inspiratory Pressure 0 to 80 cm of H20
PEEP 0 to 35 cm of H20
Inspiratory Pause 15 to 50% of Ti
O2 Blending 21 to 100%
Pressure Trigger 0.5 to 15 cm of H20 below PEEP
Flow Trigger 0.3 to 30 Ipm
Apnea Back-Up Time 5 to 60 sees

Alarms : Preset and Settable

Airway Pressure High, Low
Inspired VT High, Low
Expired Volume Low
FiO2 High, Low
PEEP High, Low
Breaths High
Apnea Alarm Time 5 to 60 seconds
Mechanical Pressure
Release Valve
90 cm of H2O

Measured Parameters

No of Breaths Spontaneous, Total Breaths
per minute
Airway Pressure Peak, Plateau, Mean, PEEP
Patient Trigger Effort Trigger Pressure, Trigger Flow
Tidal Volume Inspired, Expired
O2 Concentration Inspired O2
Graphics on 57" LCD Pressure-Time / Volume-Time / Flow-Time

Electrical and Gas Supply

Input Supply 175 to 260 Volts OR 90 to 132 Volts AC, 50/60 Hz
Internal Battery Back-Up 60 Minutes
External Battery Optional : 10 to 15 Volts DC
Power Consumption 70 Watts (Approx.) for basic ventilator
VA Requirement I I5 VA (Approx.) for basic ventilator
Gas Input Medical Grade Air & O2 at 2.7 to 6 bar (39 to 87 psi)

Physical Specifications

Dimensions 480 (W) x 290 (D) x 285 (H) mm without trolley
Weight 15 Kg for basic ventilator unit
Display 5.7" Colour TFT LCD (Internal)
Communication Output RS-485 connectivity for monitoring multiple units

Accessories

Breathing Circuit (Single Use) External TFT Monitor
Nebuliser Unit Tube Support Arm
Fluid Collection Bottle Compressor (Optional)
HME, Bacteria Filter Humidifier (Optional)
Trolley (Cart) NIV-Mask (Optional)

External TFT LCD for Enhanced Monitoring

Parameters Dynamic Airway Pressure Indication
Mode, BPM, Spont. BPM,Vti ,Vte, PEEP, Ppeak, FiO2
Graphical Display of
Lung Mechanics
Airway Pressure v/s Time
Tidal Volume v/s Time
Flow Rate v/s Time
Airway Pressure v/s Flow Rate
Tidal Volume v/s Airway Pressure
Flow Rate v/s Tidal Volume
Display Size 47 cm Wide Screen TFT LCD Monitor
Resolution 1024 x 768 Pixels
Power Consumption

30 Watts approximately

Supply Voltage 230 Volts A.C., 50 Hz